SL R230 Factory BCM Simulator

Dual-battery power supply behaviour of the vehicle power supply control module (N82/1)

CAR ASLEEP N82/1 STANDBY SIM TIME 0d 00:00:00

Instrument cluster (A1) display off

0MPH
 
 
0RPM

Power supply schematic click a fuse to blow or replace it

K57 CUT-OFF N82/1 VEHICLE POWER SUPPLY CONTROL DC/DC 15 A max CONTROL T30 monitor STANDBY   kl.30a kl.30 N73 EIS CAN-B M1 12.6 V 90% G1/4 STARTER lead-acid 35 Ah 12.2 V 43% G1 SYSTEMS AGM 70 Ah G2 14.1 V LOADS 0.0 A 12 V SOCKETS powered K75 F52f1 100 A intact intact F52f2 200 A
current drawn from a battery charging current no current

Guided demos about 30 seconds each

Settings

DOC factory trigger is about 10.8 V at terminal 30
DOC about 8 to 18 minutes of engine running; the exact value inside that range is a simulator choice
MODEL not from the documents; adjust to match your car
rest voltage 12.2 V USER
rest voltage 12.6 V
DOC 70 Ah AGM and 35 Ah lead-acid. Change them if your car has different batteries. Alternator output is fixed at 14.1 V USER